Description
IQ Aero Clean Mobile 1.0 – mobile filtration and ventilation system for a welding hood
The IQ Aero Clean Mobile 1.0 welding fume extractor is a mobile filtration and ventilation unit with a capacity of 3000 m³/h, designed to work with the IQ Air Flow welding hood. Connection via a Ø315 mm ventilation duct allows fumes and dust captured above the welding workstation to be directed straight into the filtration system.
IQ Aero Clean Mobile 1.0 is suitable for workshops and production halls where welding fumes are captured by a hood above the work area and then filtered in a mobile unit positioned next to the workstation.
Good to know before purchasing: IQ Aero Clean Mobile 1.0 requires a 400 V power supply. When planning the workstation, you should also consider the hood installation location and the routing of the Ø315 mm ventilation duct.
IQ Aero Clean Mobile 1.0 and welding hood – how does the system work?
IQ Aero Clean Mobile 1.0 works with the IQ Air Flow hood to create a filtration and ventilation system for the welding workstation. The hood positioned above the work area captures rising fumes, while Mobile 1.0 provides airflow and filtration of contaminated air.
The air captured by the hood is transported to the filtration unit through a Ø315 mm ventilation duct. With this configuration, the fumes are captured above the workstation, while the filtration unit can be positioned in a convenient location next to the workstation.
If you are setting up a workstation that uses overhead fume extraction, also choose the appropriate welding hoods. IQ Air Flow is available in various sizes, allowing the hood to be matched to the size of the workstation and work surface.
Mobile design makes it easier to organize the welding workstation
IQ Aero Clean Mobile 1.0 combines a capacity of 3000 m³/h with a wheeled design. Its mobile construction makes it easier to position the unit in relation to the hood, welding table and other elements of the workstation.
This solution is particularly practical where the layout of the production hall or workstation may change. Instead of permanently installing the filtration unit, Mobile 1.0 can be moved and repositioned according to the current layout of the workspace.
With Mobile 1.0, correct positioning of the hood above the welding area is essential. The fumes are captured by the hood and then transported through the duct to the filtration unit.
Two-stage filtration of welding fumes and dust
IQ Aero Clean Mobile 1.0 uses a spark arrestor filter and a cartridge filter with a surface area of 20 m². The two-stage system filters contaminants drawn in from the welding hood.
The filtration efficiency is 99.5% for particles with a diameter of 0.3 μm. This parameter indicates the system’s ability to capture very fine particles present in the airflow.
The spark arrestor filter is the first element of the system, while the cartridge filter provides a filtration surface area of 20 m². The modular design of the unit facilitates access to the filters during inspection, maintenance and replacement.
GPPH recommends: When combining IQ Aero Clean Mobile 1.0 with the IQ Air Flow hood, correct positioning of the hood in relation to the welding area is particularly important. Capturing fumes above the workstation limits their spread throughout the production hall and allows contaminants to be directed through the Ø315 mm duct straight to the filtration unit.
IQ Aero Clean Mobile 1.0 specifications and their importance in operation
IQ Aero Clean Mobile 1.0 delivers a capacity of 3000 m³/h and is designed to operate as a filtration and ventilation unit compatible, among others, with the IQ Air Flow welding hood.
- capacity of 3000 m³/h – ensures airflow through the filtration and ventilation system,
- filtration efficiency of 99.5% for 0.3 μm particles – indicates the system’s ability to capture fine particles,
- 20 m² cartridge filter – provides a large filtration surface area,
- spark arrestor filter – provides the first stage of filtration,
- connection to IQ Air Flow via a Ø315 mm duct – allows the creation of a system using a hood above the workstation,
- 2.2 kW motor – powers the system with a capacity of 3000 m³/h,
- 400 V power supply – requires an appropriate electrical connection,
- 60 dB at 40% power – noise level measured in the immediate vicinity of the unit housing,
- 80 dB at 100% power – noise level at full power, measured at the unit housing,
- wheeled design – makes it easier to reposition the unit,
- control panel with a display and knobs – allows the system operation to be monitored and adjusted,
- modular housing – facilitates access to the filters during maintenance.
How to connect IQ Aero Clean Mobile 1.0 to a welding hood?
IQ Aero Clean Mobile 1.0 connects to the IQ Air Flow hood via a Ø315 mm ventilation duct. The hood should be positioned above the work surface so that it captures fumes rising during welding.
The contaminated air is then transported through the duct to Mobile 1.0 and directed through the filtration system. This setup separates the fume capture point from the location of the filtration unit.
The wheeled design allows the unit to be positioned in a convenient location with regard to the installation layout, workstation organization, and access to the unit during operation and maintenance.
IQ Aero Clean Mobile 1.0 – workstation filtration and ventilation based on specific parameters
IQ Aero Clean Mobile 1.0 is manufactured in Poland and provides a capacity of 3000 m³/h, a cartridge filter surface area of 20 m², and a filtration efficiency of 99.5% for 0.3 μm particles.
The option to connect to the IQ Air Flow hood via a Ø315 mm duct makes it possible to create a system in which welding fumes are first captured above the work surface and then transported to the filtration unit.
The mobile design also makes it easier to organize the workstation and reposition the filtration unit without the need for permanent installation.
IQ Aero Clean Mobile 1.0 provides a capacity of 3000 m³/h and can operate with the IQ Air Flow hood via a Ø315 mm duct. Choose this unit for a workstation where welding fumes need to be captured above the welding area and then filtered.
Frequently Asked Questions
Can IQ Aero Clean Mobile 1.0 be connected to a welding hood?
Yes. IQ Aero Clean Mobile 1.0 can operate with the IQ Air Flow hood, and the connection is made using a Ø315 mm ventilation duct.
What is the airflow capacity of IQ Aero Clean Mobile 1.0?
IQ Aero Clean Mobile 1.0 provides an airflow of 3000 m³/h and uses a cartridge filter with a surface area of 20 m².
How does IQ Aero Clean Mobile 1.0 work with the IQ Air Flow welding hood?
The IQ Air Flow hood captures fumes above the workstation, while Mobile 1.0 transports and filters the contaminated air supplied through a Ø315 mm duct.





Opinie