IQ Aero Clean Mobile 2.0 – mobile welding fume extractor for two extraction arms
The IQ Aero Clean Mobile 2.0 welding fume extractor is a mobile filtration and ventilation unit with an airflow capacity of 3000 m³/h, designed for connection to two flexible extraction arms. This configuration allows fumes and dust to be captured as close as possible to their source and enables two extraction points or two welding workstations to be operated simultaneously.
IQ Aero Clean Mobile 2.0 is suitable for workshops and production halls where workstations change location or where one unit needs to serve more than one emission point. The wheeled design allows the unit to be moved as the work layout changes, while the flexible extraction arms enable precise positioning of the extraction point in relation to the weld being made.
Good to know before purchase: IQ Aero Clean Mobile 2.0 requires a 400 V power supply. The extraction arms are selected separately and are available in lengths of 2 m, 3 m or 4 m, allowing the configuration to be adapted to the workstation layout.
Two extraction arms – capturing fumes directly at the welding point
IQ Aero Clean Mobile 2.0 is designed to operate with two extraction arms that can be positioned directly at the points where fumes are generated. Extracting contaminants close to the source helps limit their spread throughout the workshop or production hall.
Two independent arms allow one unit to be used at two welding workstations simultaneously or both extraction points to be directed toward different areas of a larger workstation. Each arm can be positioned according to the current welding location, making it easy to adapt the system to the changing position of the workpiece or operator.
Unlike Mobile 1.0, which is designed for use with the IQ Air Flow hood, Mobile 2.0 uses local extraction arms. The 2.0 version is therefore intended primarily for situations where fumes can be captured directly at the source.
Mobile design for changing workstations
IQ Aero Clean Mobile 2.0 combines an airflow capacity of 3000 m³/h with a wheeled design, allowing the unit to be moved between workstations without permanent wall mounting.
Mobility is particularly useful in facilities where the production layout changes regularly. After moving the unit, the extraction arms can be repositioned according to the current welding points instead of modifying a fixed extraction system.
The unit itself measures 1830x1000x650 mm and weighs approximately 200 kg. These parameters apply to the unit without the extraction arms.
Two-stage filtration of welding fumes and dust
IQ Aero Clean Mobile 2.0 uses a spark arrestor filter and a cartridge filter with a surface area of 20 m². The contaminated air captured by the extraction arms is directed into the unit’s filtration system.
The filtration efficiency is 99.5% for particles measuring 0.3 μm. The spark arrestor filter forms the first stage of the system, while the cartridge filter provides further purification of the airflow.
The modular design facilitates access to the filter components during periodic inspection, maintenance, and replacement. The current specification of IQ Aero Clean units also includes a pulse-jet filter cleaning system and a vacuum gauge for monitoring the level of filter contamination.
GPPH recommends: The extraction arms should be positioned as close as possible to the point where welding fumes are generated. The sooner contaminants are captured at the source, the less fume has a chance to spread throughout the work area.
IQ Aero Clean Mobile 2.0 parameters and their importance in operation
IQ Aero Clean Mobile 2.0 provides an airflow of 3000 m³/h and can operate with two extraction arms, allowing one unit to serve two extraction points.
- airflow capacity of 3000 m³/h – provides the airflow required for local extraction of welding fumes,
- two extraction arms – allow simultaneous operation at two workstations or two emission points,
- 2, 3 or 4 m extraction arms – allow the reach to be adapted to the workstation layout,
- filtration efficiency of 99.5% for 0.3 μm particles – indicates the system’s ability to capture very fine particles,
- 20 m² cartridge filter – provides a large filtration surface area,
- spark arrestor filter – forms the first stage of the filtration system,
- 2.2 kW motor – powers the system to achieve an airflow capacity of 3000 m³/h,
- 400 V power supply – requires an appropriate electrical connection,
- 60 dB at 40% power – noise level measured in the immediate vicinity of the unit housing,
- 80 dB at 100% power – noise level when operating at full power,
- wheeled design – allows the unit to be moved between workstations,
- control panel with display and control knobs – makes it easier to monitor and adjust the unit’s operation,
- powder-coated steel – forms a durable housing designed for use in workshop and industrial environments.
How to position the extraction arms of IQ Aero Clean Mobile 2.0?
The extraction arms of IQ Aero Clean Mobile 2.0 should be positioned as close as possible to the welding area to capture fumes before they begin to rise and spread throughout the production hall. The flexible design allows the extraction point to be repositioned as the welding location changes.
With two workstations, each arm can serve a separate emission point. At one larger workstation, both arms can be used to capture contaminants generated at two different locations.
When selecting an arm length of 2, 3 or 4 m, consider the distance between the unit and the workstation as well as the range of movement required during operation. Insufficient reach will make it difficult to position the extraction hood close to the source of the fumes, so the arm length should be selected according to the actual workstation layout.
IQ Aero Clean Mobile 2.0 – one unit, two extraction points
IQ Aero Clean Mobile 2.0 is manufactured in Poland and combines an airflow capacity of 3000 m³/h, a cartridge filter surface area of 20 m², and a filtration efficiency of 99.5% for 0.3 μm particles.
The key difference of the 2.0 version is the ability to use two extraction arms, which direct contaminated air from the welding area straight to the filtration unit. This configuration allows two workstations to be served simultaneously or two emission points to be handled at one larger workstation.
The mobile design also allows the entire system to be repositioned according to the current layout of the production hall. The combination of mobility and two flexible extraction arms is particularly useful where welding locations do not remain fixed in one place.
IQ Aero Clean Mobile 2.0 provides an airflow capacity of 3000 m³/h and can operate with two extraction arms simultaneously. Choose the arm length to suit your workstation and capture fumes as close as possible to where they are generated.
Frequently Asked Questions
How many extraction arms can be connected to IQ Aero Clean Mobile 2.0?
Two extraction arms can be connected to IQ Aero Clean Mobile 2.0, allowing the unit to serve two emission points simultaneously.
What is the airflow capacity of IQ Aero Clean Mobile 2.0?
IQ Aero Clean Mobile 2.0 provides an airflow of 3000 m³/h and uses a cartridge filter with a surface area of 20 m².
What extraction arm lengths can be used with IQ Aero Clean Mobile 2.0?
The system is available with extraction arms in lengths of 2 m, 3 m and 4 m, allowing the reach to be adapted to the layout of the welding workstation.