Description
IQ Aero Clean Wall 2.0 – wall-mounted welding fume extractor for two extraction arms
The GPPH IQ Aero Clean Wall 2.0 welding fume extractor is a wall-mounted filtration and ventilation unit with an airflow capacity of 3000 m³/h, designed to operate with two extraction arms. Two extraction points allow fumes and dust to be captured as close as possible to their source, limiting the spread of contaminants throughout the workshop or production hall.
IQ Aero Clean Wall 2.0 is suitable for fixed welding workstations where the filtration unit can remain mounted on the wall while the position of the extraction points is adjusted using the arms. Wall mounting also keeps the floor space around the workstation clear.
Worth knowing before purchase: IQ Aero Clean Wall 2.0 requires a 400 V power supply and a suitable location for wall mounting. Version 2.0 is designed to operate with extraction arms, making it particularly suitable where fumes can be captured directly at the welding point.
Two extraction arms – capturing fumes directly at the source
The key feature of IQ Aero Clean Wall 2.0 is the ability to connect two extraction arms. Each arm can be positioned relative to the welding point, allowing the extraction point to remain close to the area where fumes are generated.
Two arms allow two extraction points to operate simultaneously. This solution can be used for two adjacent welding workstations or one larger workstation where welding is carried out in different areas.
After changing the welding location, the operator can adjust the position of the arm without having to move the entire filtration and ventilation unit. This keeps the unit in a fixed position while allowing the extraction point to be adapted to the work currently being performed.
Wall mounting – clear space around the workstation
IQ Aero Clean Wall 2.0 is designed for permanent wall mounting, so the filtration unit does not take up additional floor space.
This is particularly practical at workstations surrounded by welding tables, tool trolleys, materials and other equipment. Wall mounting helps keep the workspace organized and reduces the number of units positioned directly around the workstation.
Unlike the mobile version, Wall 2.0 remains in one location, making it best suited to workstations with a fixed or rarely changing layout.
Two-stage filtration of welding fumes and dust
IQ Aero Clean Wall 2.0 uses a spark arrestor filter and a cartridge filter with a surface area of 20 m². The air captured by the extraction arms is directed to the filtration system, where contaminants are removed.
The filtration efficiency is 99.5% for particles measuring 0.3 μm. The spark arrestor filter forms the first stage of the system, while the cartridge filter is responsible for further capturing fine particles.
The unit is also equipped with an anti-dust system with grating in the drawers, which helps reduce the re-suspension of accumulated contaminants during operation.
Pulse-jet system – pulse cleaning of the filter
IQ Aero Clean Wall 2.0 features a pulse-jet cleaning system that uses short pulses of compressed air to remove dust accumulated on the surface of the filter cartridge.
The pulse briefly reverses the direction of airflow through the filter, allowing accumulated dust to be dislodged and the surface of the filter cartridge to be cleaned.
The system also allows the pulse-jet operating frequency to be programmed, so the cleaning cycle can be adjusted to the intensity of the unit’s operation.
GPPH recommends: The extraction arms should be positioned as close as possible to the point where welding fumes are generated. The sooner contaminants are captured at the source, the less fume has a chance to spread throughout the work area.
Parametry IQ Aero Clean Wall 2.0 a jejich význam při práci
IQ Aero Clean Wall 2.0 provides an airflow capacity of 3000 m³/h and is designed as a stationary filtration and ventilation system using two local extraction points.
- capacity of 3000 m³/h – ensures airflow through the filtration and ventilation system,
- option to connect two extraction arms – allows fumes to be captured at two points simultaneously,
- filtration efficiency of 99.5% for 0.3 μm particles – indicates the system’s ability to capture fine particles,
- 20 m² cartridge filter – provides a large filtration surface area,
- spark arrestor filter – forms the first stage of the filtration system,
- pulse-jet system – cleans the filter using pulses of compressed air,
- programmable pulse-jet frequency – allows the cleaning cycle to be adjusted to the intensity of operation,
- anti-dust system with grating in the drawers – reduces the re-suspension of accumulated contaminants,
- 2.2 kW motor – powers the system with an airflow capacity of 3000 m³/h,
- 400 V power supply – requires an appropriate electrical connection,
- 60 dB at 40% power – noise level measured at a short distance from the unit housing,
- 80 dB at 100% power – noise level when operating at full power,
- wall mounting – keeps the floor space clear.
How to position the extraction arms of IQ Aero Clean Wall 2.0?
The extraction arms should be positioned so that the extraction points are as close as possible to where welding fumes are generated. Thanks to the adjustable position of the arms, the extraction can be adapted to the work currently being performed without changing the location of the filtration unit.
U dvou pracovišť lze každé rameno nasměrovat k samostatnému místu svařování. U jednoho většího pracoviště lze dva odsávací body využít k zachytávání dýmu z různých pracovních oblastí.
After changing the welding location, the arm should be repositioned relative to the emission source. Proper positioning of the extraction point has a direct impact on the effectiveness of local fume capture.
IQ Aero Clean Wall 2.0 – two extraction points without taking up floor space
IQ Aero Clean Wall 2.0 is manufactured in Poland and combines an airflow capacity of 3000 m³/h, a cartridge filter with a surface area of 20 m², and a filtration efficiency of 99.5% for 0.3 μm particles.
The key feature of the Wall 2.0 version is the combination of wall mounting with the option to use two extraction arms. The unit remains installed in a fixed location, while the extraction points can be positioned directly in relation to the current welding locations.
This solution allows one unit to serve two emission points while keeping the floor space around the workstation clear.
IQ Aero Clean Wall 2.0 provides an airflow capacity of 3000 m³/h and allows two extraction arms to be connected. Choose the right configuration for your workstation and capture fumes as close as possible to where they are generated.
Frequently Asked Questions
How many extraction arms can be connected to IQ Aero Clean Wall 2.0?
Two extraction arms can be connected to the IQ Aero Clean Wall 2.0, allowing the system to serve two emission points simultaneously.
What is the airflow capacity of IQ Aero Clean Wall 2.0?
IQ Aero Clean Wall 2.0 provides an airflow of 3000 m³/h and uses a cartridge filter with a surface area of 20 m².
What is the difference between IQ Aero Clean Wall 2.0 and Wall 1.0?
IQ Aero Clean Wall 2.0 works with two extraction arms, while Wall 1.0 is designed to work with a welding hood.





Opinie
Nie ma jeszcze żadnych recenzji