﻿{"id":23597,"date":"2025-08-19T08:17:00","date_gmt":"2025-08-19T06:17:00","guid":{"rendered":"https:\/\/gpph-group.com\/?post_type=product&#038;p=23597"},"modified":"2026-09-26T11:55:01","modified_gmt":"2026-09-26T09:55:01","slug":"iq-aero-clean-wall-2-0","status":"publish","type":"product","link":"https:\/\/gpph-group.com\/en_za\/p\/ventilation-devices\/welding-fume-extractors\/iq-aero-clean-wall-2-0\/","title":{"rendered":"IQ Aero Clean Wall 2.0"},"content":{"rendered":"<h2 class=\"wp-block-heading\">IQ Aero Clean Wall 2.0 \u2013 wall-mounted welding fume extractor for two extraction arms<\/h2>\n\n\n\n<p class=\" translation-block\">The <strong>GPPH IQ Aero Clean Wall 2.0<\/strong> welding fume extractor is a wall-mounted filtration and ventilation unit with an airflow capacity of <strong>3000 m\u00b3\/h<\/strong>, designed to operate with <strong>two extraction arms<\/strong>. Two extraction points allow fumes and dust to be captured as close as possible to their source, limiting the spread of contaminants throughout the workshop or production hall.<\/p>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 is suitable for <strong>fixed welding workstations<\/strong> where the filtration unit can remain mounted on the wall while the position of the extraction points is adjusted using the arms. Wall mounting also keeps the floor space around the workstation clear.<\/p>\n\n\n\n<p class=\" translation-block\"><strong>Worth knowing before purchase:<\/strong> IQ Aero Clean Wall 2.0 requires a <strong>400 V<\/strong> power supply and a suitable location for wall mounting. Version 2.0 is designed to operate with extraction arms, making it particularly suitable where fumes can be captured directly at the welding point.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E.png\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-1024x1024.png\" alt=\"Odci\u0105g spawalniczy IQ Aero Clean Wall 2.0\" class=\"wp-image-24415\" style=\"width:600px\" srcset=\"https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-1024x1024.png 1024w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-300x300.png 300w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-150x150.png 150w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-768x768.png 768w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-1536x1536.png 1536w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-12x12.png 12w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-600x600.png 600w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E-64x64.png 64w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-2.0-E.png 2000w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Two extraction arms \u2013 capturing fumes directly at the source<\/h2>\n\n\n\n<p class=\" translation-block\">The key feature of IQ Aero Clean Wall 2.0 is the ability to connect <strong>two extraction arms<\/strong>. Each arm can be positioned relative to the welding point, allowing the extraction point to remain close to the area where fumes are generated.<\/p>\n\n\n\n<p class=\" translation-block\">Two arms allow <strong>two extraction points to operate simultaneously<\/strong>. This solution can be used for two adjacent welding workstations or one larger workstation where welding is carried out in different areas.<\/p>\n\n\n\n<p>After changing the welding location, the operator can adjust the position of the arm without having to move the entire filtration and ventilation unit. This keeps the unit in a fixed position while allowing the extraction point to be adapted to the work currently being performed.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Wall mounting \u2013 clear space around the workstation<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 is designed for <strong>permanent wall mounting<\/strong>, so the filtration unit does not take up additional floor space.<\/p>\n\n\n\n<p>This is particularly practical at workstations surrounded by welding tables, tool trolleys, materials and other equipment. Wall mounting helps keep the workspace organized and reduces the number of units positioned directly around the workstation.<\/p>\n\n\n\n<p class=\" translation-block\">Unlike the mobile version, <strong>Wall 2.0 remains in one location<\/strong>, making it best suited to workstations with a fixed or rarely changing layout.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Two-stage filtration of welding fumes and dust<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 uses a <strong>spark arrestor filter and a cartridge filter with a surface area of 20 m\u00b2<\/strong>. The air captured by the extraction arms is directed to the filtration system, where contaminants are removed.<\/p>\n\n\n\n<p class=\" translation-block\">The filtration efficiency is <strong>99.5% for particles measuring 0.3 \u03bcm<\/strong>. The spark arrestor filter forms the first stage of the system, while the cartridge filter is responsible for further capturing fine particles.<\/p>\n\n\n\n<p class=\" translation-block\">The unit is also equipped with an <strong>anti-dust system with grating in the drawers<\/strong>, which helps reduce the re-suspension of accumulated contaminants during operation.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Pulse-jet system \u2013 pulse cleaning of the filter<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 features a <strong>pulse-jet cleaning system<\/strong> that uses short pulses of compressed air to remove dust accumulated on the surface of the filter cartridge.<\/p>\n\n\n\n<p>The pulse briefly reverses the direction of airflow through the filter, allowing accumulated dust to be dislodged and the surface of the filter cartridge to be cleaned.<\/p>\n\n\n\n<p class=\" translation-block\">The system also allows the <strong>pulse-jet operating frequency to be programmed<\/strong>, so the cleaning cycle can be adjusted to the intensity of the unit\u2019s operation.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>GPPH recommends:<\/strong> The extraction arms should be positioned as close as possible to the point where welding fumes are generated. The sooner contaminants are captured at the source, the less fume has a chance to spread throughout the work area.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Parametry IQ Aero Clean Wall 2.0 a jejich v\u00fdznam p\u0159i pr\u00e1ci<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 provides an <strong>airflow capacity of 3000 m\u00b3\/h<\/strong> and is designed as a stationary filtration and ventilation system using two local extraction points.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\" translation-block\"><strong>capacity of 3000 m\u00b3\/h<\/strong> \u2013 ensures airflow through the filtration and ventilation system,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>option to connect two extraction arms<\/strong> \u2013 allows fumes to be captured at two points simultaneously,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>filtration efficiency of 99.5% for 0.3 \u03bcm particles<\/strong> \u2013 indicates the system\u2019s ability to capture fine particles,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>20 m\u00b2 cartridge filter<\/strong> \u2013 provides a large filtration surface area,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>spark arrestor filter<\/strong> \u2013 forms the first stage of the filtration system,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>pulse-jet system<\/strong> \u2013 cleans the filter using pulses of compressed air,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>programmable pulse-jet frequency<\/strong> \u2013 allows the cleaning cycle to be adjusted to the intensity of operation,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>anti-dust system with grating in the drawers<\/strong> \u2013 reduces the re-suspension of accumulated contaminants,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>2.2 kW motor<\/strong> \u2013 powers the system with an airflow capacity of 3000 m\u00b3\/h,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>400 V power supply<\/strong> \u2013 requires an appropriate electrical connection,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>60 dB at 40% power<\/strong> \u2013 noise level measured at a short distance from the unit housing,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>80 dB at 100% power<\/strong> \u2013 noise level when operating at full power,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>wall mounting<\/strong> \u2013 keeps the floor space clear.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">How to position the extraction arms of IQ Aero Clean Wall 2.0?<\/h2>\n\n\n\n<p class=\" translation-block\">The extraction arms should be positioned so that the extraction points are <strong>as close as possible to where welding fumes are generated<\/strong>. Thanks to the adjustable position of the arms, the extraction can be adapted to the work currently being performed without changing the location of the filtration unit.<\/p>\n\n\n\n<p>U dvou pracovi\u0161\u0165 lze ka\u017ed\u00e9 rameno nasm\u011brovat k samostatn\u00e9mu m\u00edstu sva\u0159ov\u00e1n\u00ed. U jednoho v\u011bt\u0161\u00edho pracovi\u0161t\u011b lze dva ods\u00e1vac\u00ed body vyu\u017e\u00edt k zachyt\u00e1v\u00e1n\u00ed d\u00fdmu z r\u016fzn\u00fdch pracovn\u00edch oblast\u00ed.<\/p>\n\n\n\n<p>After changing the welding location, the arm should be repositioned relative to the emission source. Proper positioning of the extraction point has a direct impact on the effectiveness of local fume capture.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">IQ Aero Clean Wall 2.0 \u2013 two extraction points without taking up floor space<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 is <strong>manufactured in Poland<\/strong> and combines an airflow capacity of <strong>3000 m\u00b3\/h<\/strong>, a cartridge filter with a surface area of <strong>20 m\u00b2<\/strong>, and a filtration efficiency of <strong>99.5% for 0.3 \u03bcm particles<\/strong>.<\/p>\n\n\n\n<p class=\" translation-block\">The key feature of the Wall 2.0 version is the combination of <strong>wall mounting with the option to use two extraction arms<\/strong>. The unit remains installed in a fixed location, while the extraction points can be positioned directly in relation to the current welding locations.<\/p>\n\n\n\n<p>This solution allows one unit to serve two emission points while keeping the floor space around the workstation clear.<\/p>\n\n\n\n<p class=\" translation-block\"><strong>IQ Aero Clean Wall 2.0 provides an airflow capacity of 3000 m\u00b3\/h and allows two extraction arms to be connected.<\/strong> Choose the right configuration for your workstation and capture fumes as close as possible to where they are generated.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">How many extraction arms can be connected to IQ Aero Clean Wall 2.0?<\/h3>\n\n\n\n<p class=\" translation-block\"><strong>Two extraction arms can be connected to the IQ Aero Clean Wall 2.0<\/strong>, allowing the system to serve two emission points simultaneously.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the airflow capacity of IQ Aero Clean Wall 2.0?<\/h3>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 provides an <strong>airflow of 3000 m\u00b3\/h<\/strong> and uses a cartridge filter with a surface area of <strong>20 m\u00b2<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the difference between IQ Aero Clean Wall 2.0 and Wall 1.0?<\/h3>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 2.0 works with <strong>two extraction arms<\/strong>, while Wall 1.0 is designed to work with a welding hood.<\/p>","protected":false},"excerpt":{"rendered":"<p>IQ Aero Clean Wall 2.0 is an air filtration system that effectively removes smoke, dust, and other pollutants. It improves air quality in the workplace, supporting employee health and comfort \u2013 ideal for workshops, production halls, and other demanding environments.<\/p>","protected":false},"featured_media":23602,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[178,126],"product_tag":[],"class_list":{"0":"post-23597","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-odciagi-spawalnicze","7":"product_cat-urzadzenia-wentylacyjne","8":"product_shipping_class-stol-spawalniczy-2000","9":"pa_material-wykonania-stal-malowana-proszkowo","10":"pa_moc-silnika-kw-322","11":"pa_napiecie-400-v","12":"pa_poziom-halasu-40-60-db-100-80-db","13":"pa_system-iq-flow-control-adaptacyjna-regulacja-przeplywu-powietrza","14":"pa_typ-filtracji-filtr-przeciwiskrowy-filtr-patronowy-o-powierzchni-20m2","15":"pa_wydajnosc-przeplywu-powietrza-3000-m3-h","17":"first","18":"instock","19":"sale","20":"taxable","21":"shipping-taxable","22":"purchasable","23":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/product\/23597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/comments?post=23597"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/media\/23602"}],"wp:attachment":[{"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/media?parent=23597"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/product_brand?post=23597"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/product_cat?post=23597"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gpph-group.com\/en_za\/wp-json\/wp\/v2\/product_tag?post=23597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}