﻿{"id":23594,"date":"2025-08-19T08:13:00","date_gmt":"2025-08-19T06:13:00","guid":{"rendered":"https:\/\/gpph-group.com\/?post_type=product&#038;p=23594"},"modified":"2026-09-26T09:04:00","modified_gmt":"2026-09-26T07:04:00","slug":"iq-aero-clean-wall-1-0","status":"publish","type":"product","link":"https:\/\/gpph-group.com\/en_nz\/p\/ventilation-devices\/welding-fume-extractors\/iq-aero-clean-wall-1-0\/","title":{"rendered":"IQ Aero Clean Wall 1.0"},"content":{"rendered":"<h2 class=\"wp-block-heading\">IQ Aero Clean Wall 1.0 \u2013 wall-mounted filtration and ventilation system for a welding hood<\/h2>\n\n\n\n<p class=\" translation-block\">The <strong>IQ Aero Clean Wall 1.0<\/strong> welding fume extractor is a filtration and ventilation unit with an airflow capacity of <strong>3000 m\u00b3\/h<\/strong>, designed for permanent wall mounting and operation with a welding hood. This solution allows fumes and dust to be captured above the welding workstation and then directs the contaminated air to the filtration unit.<\/p>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 is particularly suitable for <strong>fixed welding workstations<\/strong> where the work layout does not require the unit to be moved. Wall mounting also keeps the floor space clear and helps organize equipment around the workstation.<\/p>\n\n\n\n<p class=\" translation-block\"><strong>Good to know before purchase:<\/strong> IQ Aero Clean Wall 1.0 requires a <strong>400 V<\/strong> power supply and is designed to operate with a welding hood. When planning the workstation, consider both the wall mounting location of the unit and the position of the hood above the work area.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B.png\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-1024x1024.png\" alt=\"\" class=\"wp-image-24419\" style=\"width:600px\" srcset=\"https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-1024x1024.png 1024w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-300x300.png 300w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-150x150.png 150w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-768x768.png 768w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-1536x1536.png 1536w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-12x12.png 12w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-600x600.png 600w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B-64x64.png 64w, https:\/\/gpph-group.com\/wp-content\/uploads\/2025\/08\/IQ-Aero-Clean-Wall-1.0-B.png 2000w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">IQ Aero Clean Wall 1.0 and welding hood \u2013 how does the system work?<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 operates with a <strong>welding hood<\/strong> positioned above the work area to capture rising fumes and dust. The contaminated air is then directed to the Wall 1.0 unit, where it passes through the filtration system.<\/p>\n\n\n\n<p>This solution allows the contaminant capture point to be separated from the location where the filtration unit is installed. The hood captures fumes above the workstation, while Wall 1.0 provides the required airflow and filtration.<\/p>\n\n\n\n<p class=\" translation-block\">If you are planning a workstation with overhead fume capture, also select suitable GPPH <strong>welding hoods<\/strong> according to the size of the workstation and work surface.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Wall mounting \u2013 more free space around the workstation<\/h2>\n\n\n\n<p class=\" translation-block\">The main difference between IQ Aero Clean Wall 1.0 and the mobile version is its <strong>permanent wall mounting<\/strong>. The filtration and ventilation unit does not take up floor space, allowing the area around the workstation to be used for a welding table, tool trolleys, materials or other equipment.<\/p>\n\n\n\n<p>Wall mounting works well in workshops and production halls where the workstation has a fixed location. Eliminating the need to move the unit simplifies work organization, while the filtration unit remains permanently connected to the extraction system.<\/p>\n\n\n\n<p>The fixed position of Wall 1.0 also helps reduce the number of items placed on the floor, which is important in heavily used production workstations.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Two-stage filtration of welding fumes and dust<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 uses a <strong>spark arrestor filter and a cartridge filter with a surface area of 20 m\u00b2<\/strong>. The system is responsible for filtering the air drawn in from the welding hood.<\/p>\n\n\n\n<p class=\" translation-block\">The filtration efficiency is <strong>99.5% for particles measuring 0.3 \u03bcm<\/strong>. The spark arrestor filter provides the first stage of system protection, while the cartridge filter is responsible for capturing finer contaminants.<\/p>\n\n\n\n<p class=\" translation-block\">The unit is also equipped with an <strong>anti-dust system with grating in the drawers<\/strong>, which helps reduce the re-suspension of accumulated contaminants during operation.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Pulse-jet system \u2013 automatic filter cleaning<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 features a <strong>pulse-jet cleaning system<\/strong> that uses short bursts of compressed air to remove dust accumulated on the surface of the filter cartridge.<\/p>\n\n\n\n<p>The pulse briefly reverses the direction of airflow through the filter, causing the accumulated dust to be dislodged from its surface. This solution helps maintain proper filter operating conditions without the need for frequent manual cleaning.<\/p>\n\n\n\n<p class=\" translation-block\">The system also allows you to <strong>program the cleaning cycle frequency<\/strong>, so the pulse-jet operation can be adjusted to the intensity of use of the unit.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p><strong>GPPH recommends:<\/strong> With the Wall 1.0 + welding hood system, correct positioning of the hood above the welding area is crucial. Fumes should be captured as soon as possible after they are generated, before they begin to spread throughout the production hall or workshop.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">IQ Aero Clean Wall 1.0 parameters and their importance in operation<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 provides an <strong>airflow capacity of 3000 m\u00b3\/h<\/strong> and is designed as a stationary filtration and ventilation unit for operation with a welding hood.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\" translation-block\"><strong>airflow capacity of 3000 m\u00b3\/h<\/strong> \u2013 provides the airflow required for the operation of the filtration and ventilation system,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>filtration efficiency of 99.5% for 0.3 \u03bcm particles<\/strong> \u2013 indicates the system\u2019s ability to capture very fine particles,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>20 m\u00b2 cartridge filter<\/strong> \u2013 provides a large filtration surface area,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>spark arrestor filter<\/strong> \u2013 forms the first stage of the filtration system,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>pulse-jet system<\/strong> \u2013 cleans the filter cartridge using pulses of compressed air,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>programmable pulse-jet frequency<\/strong> \u2013 allows the cleaning cycle to be adjusted to operating conditions,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>anti-dust system with grating in the drawers<\/strong> \u2013 helps reduce the re-suspension of accumulated contaminants,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>2.2 kW motor<\/strong> \u2013 powers the system to achieve an airflow capacity of 3000 m\u00b3\/h,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>400 V power supply<\/strong> \u2013 requires an appropriate electrical connection,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>60 dB at 40% power<\/strong> \u2013 noise level measured at a short distance from the unit housing,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>80 dB at 100% power<\/strong> \u2013 noise level when operating at full power,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>wall mounting<\/strong> \u2013 helps keep the floor space clear,<\/li>\n\n\n\n<li class=\" translation-block\"><strong>powder-coated steel<\/strong> \u2013 forms a housing designed for workshop and industrial environments.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">How to plan a workstation with IQ Aero Clean Wall 1.0?<\/h2>\n\n\n\n<p>IQ Aero Clean Wall 1.0 is best suited to workstations with a fixed layout, where the unit can remain installed in one location. When planning the installation, consider both the appropriate location of the unit on the wall and the position of the hood in relation to the work surface.<\/p>\n\n\n\n<p>The hood should capture fumes rising during welding before the contaminants begin to spread throughout the room. The captured air is then directed to the Wall 1.0 unit and passes through the filtration system.<\/p>\n\n\n\n<p class=\" translation-block\">This solution works well where there is no need to move the unit between different workstations and the priority is a <strong>permanent filtration and ventilation system while keeping the floor space clear<\/strong>.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">IQ Aero Clean Wall 1.0 \u2013 stationary filtration and ventilation at the welding workstation<\/h2>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 is <strong>manufactured in Poland<\/strong> and combines an airflow capacity of <strong>3000 m\u00b3\/h<\/strong>, a cartridge filter surface area of <strong>20 m\u00b2<\/strong> and a filtration efficiency of <strong>99.5% for 0.3 \u03bcm particles<\/strong>.<\/p>\n\n\n\n<p class=\" translation-block\">The key feature of the Wall 1.0 variant is its <strong>wall-mounted design and operation with a welding hood<\/strong>. The hood captures fumes above the welding area, while the unit provides the airflow and filtration of contaminated air.<\/p>\n\n\n\n<p>The pulse-jet system helps maintain the filter in proper operating conditions, while wall mounting eliminates the need to place an additional unit on the floor next to the workstation.<\/p>\n\n\n\n<p class=\" translation-block\"><strong>IQ Aero Clean Wall 1.0 provides an airflow capacity of 3000 m\u00b3\/h and operates with a welding hood at a fixed workstation.<\/strong> Choose this system for a workstation where overhead fume capture and keeping the area around the welding zone clear are important.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Does IQ Aero Clean Wall 1.0 work with a welding hood?<\/h3>\n\n\n\n<p class=\" translation-block\">Yes. <strong>IQ Aero Clean Wall 1.0 is designed to operate with a welding hood<\/strong> that captures fumes above the work surface.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the airflow capacity of IQ Aero Clean Wall 1.0?<\/h3>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 provides an <strong>airflow of 3000 m\u00b3\/h<\/strong> and uses a cartridge filter with a surface area of <strong>20 m\u00b2<\/strong>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">How does IQ Aero Clean Wall 1.0 differ from the Mobile version?<\/h3>\n\n\n\n<p class=\" translation-block\">IQ Aero Clean Wall 1.0 is <strong>wall-mounted<\/strong>, so it remains at a fixed workstation and does not take up additional floor space.<\/p>","protected":false},"excerpt":{"rendered":"<p>IQ Aero Clean Wall 1.0 is an air filtration system that effectively removes smoke, dust, and other pollutants. It improves air quality in the workplace, supporting employee health and comfort \u2013 ideal for workshops, production halls, and other demanding environments.<\/p>","protected":false},"featured_media":23596,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[178,126],"product_tag":[],"class_list":{"0":"post-23594","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-odciagi-spawalnicze","7":"product_cat-urzadzenia-wentylacyjne","8":"product_shipping_class-stol-spawalniczy-2000","9":"pa_material-wykonania-stal-malowana-proszkowo","10":"pa_moc-silnika-kw-322","11":"pa_napiecie-400-v","12":"pa_poziom-halasu-40-60-db-100-80-db","13":"pa_system-iq-flow-control-adaptacyjna-regulacja-przeplywu-powietrza","14":"pa_typ-filtracji-filtr-przeciwiskrowy-filtr-patronowy-o-powierzchni-20m2","15":"pa_wydajnosc-przeplywu-powietrza-3000-m3-h","17":"first","18":"instock","19":"sale","20":"taxable","21":"shipping-taxable","22":"purchasable","23":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/product\/23594","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/comments?post=23594"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/media\/23596"}],"wp:attachment":[{"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/media?parent=23594"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/product_brand?post=23594"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/product_cat?post=23594"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gpph-group.com\/en_nz\/wp-json\/wp\/v2\/product_tag?post=23594"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}